Can We Trust Operando Data? Stack Pressure, Beam Damage and the Controls That Matter
中文 Putting a battery in a synchrotron beam and recording voltage alongside diffraction does not automatically reveal its undisturbed reaction. Stack pressure can change contact conditions during cycling, while the X-ray beam can make the irradiated region lag behind the rest of the electrode. Without controls, an unusual phase trajectory may include contributions from fixture relaxation or beam interaction. Two open studies make this problem concrete. The 2026 APTOX sample-environment paper b...
Reading XANES Maps: Why a More Uniform Solid-State Cathode Can Have More Pores
中文 A smooth voltage curve can average together particles that are deeply delithiated, particles that have barely started reacting, and particles that contribute little capacity. Synchrotron XANES imaging puts those differences back into space. A red–green map alone, however, does not tell us whether the cause is slow bulk diffusion, interfacial decomposition, or loss of contact. Park and colleagues addressed this problem using single-crystal NCM622, Li₆PS₅Cl solid electrolyte, and a Li–In cou...
Not every crack is equally dangerous: mapping solid-state battery failure with synchrotron tomography
中文 A crack in a tomographic image is only the beginning of an explanation for a solid-state battery short circuit. Does it span the electrolyte thickness? Has nearby material reacted? Is the local region under tension or compression? Was the defect created during cycling, or inherited from processing and assembly? A grayscale slice alone cannot usually resolve these questions. The study by Hu and colleagues in Advanced Energy Materials combines X-ray micro-computed tomography, μ-CT, with diff...
How Sulfide Interphases Hinder Lithium Transport: Reading the XAS Evidence
中文 High ionic conductivity does not guarantee a stable interface in a sulfide solid-state battery. The harder question is what happens when the electrolyte itself reacts at a charging potential: why can the resulting interphase impede lithium-ion transport without fully stopping further decomposition? Calling it “electrolyte degradation” identifies the problem but does not connect electrochemistry, local bonding and transport. The 2024 paper by Cao and colleagues in Cell Reports Physical Scie...
Fitting EXAFS in Artemis: paths, coordination numbers, and what counts as a result
Shell fitting of extended X-ray absorption fine structure (EXAFS) is commonly done in Artemis, part of the Demeter package. Athena turns an experimental spectrum into a file Artemis can import. Artemis then lines the measured oscillation up with scattering paths from FEFF, and from that estimates the coordination number NNN, a distance correction, the disorder σ2\sigma^2σ2, and the energy-origin shift ΔE0\Delta E_0ΔE0. The interface, the order of operations, and three examples are kept apart...
Characterising battery materials: structure, surface, and in-situ measurements
Battery-material characterisation usually falls into three layers. Diffraction and electron microscopy read structure and morphology. Raman spectroscopy and X-ray photoelectron spectroscopy (XPS) read chemical state. In-situ diffraction and absorption read the charge–discharge process. In an all-solid-state cell the interface reactions often sit inside the sample, so that part leans on synchrotron X-ray diffraction (SXRD) and X-ray absorption spectroscopy (XAS), which can penetrate the cell. ...
Synchrotron measurements of all-solid-state batteries: electrolytes, interfaces, and failure
All-solid-state lithium-ion batteries (ASSLIBs) replace the liquid electrolyte with a solid electrolyte (SE). Both the electrodes and the electrolyte are solids, so the interfaces are buried. Side reactions, poor contact, and lithium dendrites are hard to see directly. Synchrotron X-rays can do diffraction, absorption spectroscopy, and imaging in the same facility, which is why they are used to watch bulk ion transport and how a solid–solid interface changes during cycling. The cases below ar...
Thirteen ways to read a XANES spectrum
The near-edge structure (XANES) of an X-ray absorption spectrum can be used to discuss the local chemical environment of the absorbing atom. The thirteen questions below are grouped as structure and speciation, quantitative analysis, and how a spectrum changes. The thirteen questions Approach What is observed Example or question Coordination edge and near-edge shape separate valence, coordination number, or geometry Crystallinity spectral shape crystalline versus amorphous SiO2\mathr...
GIWAXS of thin-film crystallisation and orientation
Grazing-incidence wide-angle X-ray scattering (GIWAXS) is suited to molecular packing, crystal orientation, and crystallisation in thin films. This note keeps the composition ratios, spectral parameters, and times reported for D18/BTP-eC9-4F organic films, and lines them up with the other measurements in the same source. What GIWAXS measures Synchrotron X-rays hit the film at a grazing angle of about 0.1°–1°. The source states that the evanescent wave from total reflection at the interface ca...
A synchrotron is the light source; XAS is the measurement
Synchrotron radiation (SR) and X-ray absorption spectroscopy (XAS) are often mentioned together, but they are not the same object. A synchrotron is a light source. XAS is an experiment that uses X-rays interacting with matter to analyse a sample. The synchrotron: a source of tunable X-rays Synchrotron radiation is the electromagnetic radiation emitted along the tangent when a fast charged particle is deflected in a magnetic field. In 1947, researchers saw the intense radiation produced when h...